Surface Measure 1008S
Non-Contact Line-Laser Sensor SM1008SItem number: 553-100
Surface Measure 1008S
Non-Contact Line-Laser Sensor SM1008SItem number: 553-100
Stand-alone non-contact line-laser sensor
Main benefits:
- High accuracy and environment-resistant sensor
- Supporting automated measurement
- Excellent operability simply by using a mouse
- Simple and intuitive interface
- Web-browser based, no need to install software
- Various built-in measurement
- 2D and 3D data can be obtained
*1 Accuracy inspection environment: Temperature 20°C ± 1°C, Humidity 50%RH ± 10%RH
Measurement workpieces: Specified reference ball for inspection (Φ30 mm)
Inspection method: Determined by Mitutoyo-specified inspection method.
The operating environment and the storage environment are different from the guaranteed accuracy environment.
*2 Measuring accuracy may deteriorate if any water droplet or dust particle adheres to the optical path.
Stand-alone non-contact line-laser sensor
Main benefits:
- High accuracy and environment-resistant sensor
- Supporting automated measurement
- Excellent operability simply by using a mouse
- Simple and intuitive interface
- Web-browser based, no need to install software
- Various built-in measurement
- 2D and 3D data can be obtained
*1 Accuracy inspection environment: Temperature 20°C ± 1°C, Humidity 50%RH ± 10%RH
Measurement workpieces: Specified reference ball for inspection (Φ30 mm)
Inspection method: Determined by Mitutoyo-specified inspection method.
The operating environment and the storage environment are different from the guaranteed accuracy environment.
*2 Measuring accuracy may deteriorate if any water droplet or dust particle adheres to the optical path.
Maximum measuring width: | 100 mm
|
Measuring range: | 80 mm
|
Working distance: | 80 mm
|
Scanning error (1ơ)*¹: | 20 µm
|
Frame rate: | Max. 10kHz
|
Laser Class EN/IEC: | CLASS 2 (EN/IEC 60825-1:2014)
|
Laser Class JIS: | CLASS 2 (JIS C 6802:2014)
|
Line Laser Medium: | Semiconductor laser
|
Line Laser Wavelength: | 405nm (visible)
|
Line Laser Max. Power: | 2.2 mW
|
Operating Environment Temperature: | 0°C to 40°C
|
Operating Environment Humidity: | RH 20% to 80%, non-condensing
|
Storage Environment Temperature: | -30°C to 70°C
|
Storage Environment Humidity: | RH 20% to 95%, non-condensing
|
IP Protection Class: | IP67*²
|
Power supply: | 24V to 48VDC (15W)
|
Mass: | 650g
|