Please select an Excel (.xls; .xlsx) or CSV file (.txt; .csv; .tab):
Reset shopping cart prior to importing:
The first line contains labels; ignore them:
Number of the column with the article number:
Number of the column with the quantity:
Separation characters (relevant for *.csv files):
Disclaimer
Before attempting to access a User's Manual on this website please read the following conditions. If you agree entirely with these conditions you may proceed to access the online manuals.
  • These online manuals are copyrighted by Mitutoyo Corporation (hereinafter referred to as our company).
  • No User's Manual accessible from this website may be reproduced, in part or in whole, or modified in any manner without the prior permission of our company.
  • The User's Manuals on this website are intended to be representative of those that are supplied with measuring tools such as micrometers and calipers currently available for sale, but this website does not provide all manuals for our current product lineup on the market. If any particular product manual cannot be found on this website please contact your dealer directly to arrange purchase of that manual.
  • The manuals released to this website may not be modified or updated each time the manuals are revised.
  • Printed materials, such as Operation Guides, that supplement a User's Manual may be supplied with a product. Please take note that these materials will not be released to this website.
  • Product appearance and specifications, as described in the User's Manuals, are subject to change and the production and distribution of any product may be discontinued without notice.
  • Service on this website is subject to discontinuation or change in contents or conditions without notice.
  • The User's Manuals on this website are online documents for customers who have purchased our company's products. Please take note that our company may not respond to inquiries from sources other than our customers.
  • Our company shall have neither liability nor responsibility to any person or entity with respect to any direct or indirect loss or damage (including damage due to data corruption, interruption of work, etc.) arising from use or nonuse of this website service even if our company has been previously notified of the occurrence of such loss or damage or the possibility of damage claim from a third party.
  • The safety precautions described in the User's Manuals are subject to change in accordance with any change in legal regulations.

Vickers hardness testing machine

HV-110 System main unit A-type

Item number: 810-440D

j_hv-100series_pho02_s.eps
j_hv-100series_pho02_s.eps
810-401d_1.jpg
810-401d_2.jpg
app_2.jpg
vickers_indent.jpg

Vickers hardness testing machine

HV-110 System main unit A-type

Item number: 810-440D

Price on application
Description

The manual line up of the HV-100 Series has the following benefits:

  • 144 mm (5.7 inch) colored touchsreen display (Type A) with higher visibility, easy to operate user interface
  • Digimatic output for report creation.
  • USB stick data export
  • Electronic test force change.
  • Max. specimen height up to 210mm 
  • LED illumination for best image. 
  • High number of accessories
  • Vickers, Knoop, Brinell and KC fracture toughness measurement.
  • Supports Brinelltest up to 62,5KG with an optional test force weight.

The manual line up of the HV-100 Series has the following benefits:

  • 144 mm (5.7 inch) colored touchsreen display (Type A) with higher visibility, easy to operate user interface
  • Digimatic output for report creation.
  • USB stick data export
  • Electronic test force change.
  • Max. specimen height up to 210mm 
  • LED illumination for best image. 
  • High number of accessories
  • Vickers, Knoop, Brinell and KC fracture toughness measurement.
  • Supports Brinelltest up to 62,5KG with an optional test force weight.
Test force:
N: 9,807; 19,61; 29,42; 49,03;
98,07; 196,1; 294,2; 490,3
(kgf): 1; 2; 3; 5; 10; 20; 30; 50
External dimensions
[mm]:
System A: 307(W)×696(D)×786(H)mm System B/C/D: 307(W)×627(D)×875(H)mm
Objective lens:
Up to 3 pcs. mountable (one standard lens 10X mounted as standard)
Force dwell time:
5-999 sec (selectable)
Optical system:
Infinity corrected optical system
Illumination unit:
LED light
Standard:
JIS B 7725, ISO 6507-2
Data output:
RS-232C, Digimatic, USB 2. 0 interface
Indenter approach speed:
60 µm/s, 150 µm/s selectable
Control panel:
Built-in touch panel, 5.7" Color LCD (HM-110A/120A for System A), Control software (PC for System B/C/D)
Functions:
Calculation of Vickers / Knoop*2 / Brinell*3 hardness, and ceramic fracture toughness based on IF method (JIS R1697),
3 display format (standard, list, simple), GO/NG judgment, test condition guide, curve and user correction,
hardness corresponding value, statistics calculation
Main unit mass:
HV-110: Approx. 60kg, HV-120: Approx. 58kg
Output:
Digimatic, serial, USB2.0 series A (for memory)*1, USB2.0 B Type (for system communication)
Resolution of diagonal
length of an indentation:
Objective lens less than 50X: 0.1μm (Objective lens more than 50X: 0.01μm)
Specimen dimensions:
System A: height 210mm, depth 170mm (when using flat anvil)
System B: height 181mm, depth 170mm (when using manual XY stage 50X50mm)
System C: height 172mm, depth 170mm, System D: height 132mm, depth 170mm
Test force control:
Lever method and automatic control (load, duration, unload)
Turret drive:
Motor driven and manual operation
Power supply report:
UN 38.3 Test Summary Report
*VAT excluded. All products are intended to be sold to commercial customers.
Product illustrations are without obligation. Product descriptions, in particular any and all technical specifications, are only binding when explicitly agreed upon.